Update firmware
3 Copy the latest Diamond-VT image file
(“...”.ima) onto the host computer and note its
directory
c:\diamond\flash\“...”.ima
4 Change directories to the place where you
copied the “...”.ima file
cd c:\diamond\flash
5 Open an FTP session using a user-defined IP
address or the default (10.0.0.1) if it has not
changed. The IP address must be a valid
address for your network.
6 At the FTP login prompt, type sysadmin as the
userID.
7 Press Enter at the password prompt.
8Type put “...”.ima.
The Diamond should acknowledge receiving
the file and display a message not to interrupt
power for 90 seconds.
9 If upgrading the firmware from versions older
than 2.5.3, follow the procedures outlined in
Resetting Defaults
on page 63.
10 When the flash procedure is complete, cycle
power on the Diamond-VT.
CAUTIONCAUTION
Do not interrupt the flash process. If the
process is interrupted, the Diamond-VT
will become inoperable and will have to
be returned to the factory for repair.
Do not turn off the Diamond-VT until the
display returns the Ready prompt.